Flue gas analyzer MRU Delta Smart Model B
in DynaCase THL flat Design
order number: 99012067
plus Shipping-costs: after expenditure (see Standard business conditions)
open description
scope of delivery:
- Flue gas analyzer MRU Delta Smart Model B
- Pocket Star filter for condensate trap
- Infrared thermal printer (Speed Printer)
- DynaCase Instrument case MRU Delta Samrt flat design
Modern and powerful flue gas analyser for residential and commercial heating installations
Outstanding benefits:
Modern technology, high accuracy and performance
Field replaceable plug&play sensors due to new MSM-technology
Colour and backlit touchscreen, intuitive and easy to use
Up to 3 electrochemical cells for O2, CO and NO
TÜV pending according to 1. BimSchV and EN 50379/1+2
- O2-sensor
- CO-Sensor, non-H2-compensated (using CO sensor version E)
- CO-Sensor, H2-compensated (using CO sensor version B)
- MSM sensor technology for field replaceable, plug & play sensors
- Gas temperature measurement up to 1200°C with K-type thermocouple
- Combustion air temperature 0 - 100°C with K-type thermocouple
- Stack / Differential pressure: ± 100 mbar
- Differential temperature mesurement
- Ambient air CO tester
- Gas sampling probe with fixed Ø 8 x 250 mm stainless steel tube and 1,5 m triple silicone gas sampling hose
- Large condensate trap with Teflon coated particulate filter
- High capacity, Lithium-Ion rechargeable battery
- Mini-USB interface to PC and SD card slot for large volume data logging
- Internal data storage for up to 1.000 measurements
- IRDA printer interface
- O2
- 0 ... 21,0 % Vol-% abs., resolution 0,1 %
CO (H2 compensated)
- 0 ... 4.000 ppm (overload up to 10.000 ppm), resolution 1 ppm
CO
- 0 ... 2.000 ppm (overload up to 4.000 ppm), resolution 1 ppm
NO
- 0 ... 1.000 ppm (overload up to 5.000 ppm), resolution 1 ppm
Fluegas temperature
- -40 ... +1.200 °C, resolution 0,1°C
- -40 ... +1.200 °C, resolution 0,1 °C
- 0 ... 100 °C, resolution 0,1 °
- ± 50 hPa, resolution 0,01 hPa
- ± 100 hPa (mbar), resolution 0,01 hPa
- Ambient CO, analyser leak test
- CO2, heat losses, combustion efficiency, dew point
- Natural gas, light oil, wood dry, pellets and others
- 0 ... 20 %
- °C, resolution 0,1 °
- 0 ... 99,9 %, resolution 0,1 %
- 0 ... 120 %, resolution 0,1 %
- 1 ... 9,99 %, resolution 0,01 %
- Ø 8 x 250 mm, stainless steel, for temperature up to 650 °C
- +5 ... +45 °C, max. 95 % RF, not condensing
- -20 ... +50 °C
- 1.000 measurements / 1.000 sites
- Mini-USB, Micro-SD, IRDA, Bluetooth (data transfer to Smartphone, Tablet or PC)
- Li-Ion 2250 mAh / 8 Wh
- Wall plug 100 ... 240 Vac / 50 ... 60 Hz, 5 V DC, 500 mA
- IP 40
- approx. 390 g (without probe)
- (W x H x D) 82 x 169 x 44 mm
Differential temperature
Combustion air temperature
Draught
Differential pressure
Other measurements
Combustion relevant calculations
Fuel types
CO2
Dew point
Heat losses qA
Combustion efficiency
Excess air
Gas sampling probe
Operating temperature
Storage temperature
Data storage
Interfaces
Internal power supply
External power supply
Protection
Weight
Dimensions
close description