0521 30443-0
Mon-Thu 7.30 - 18.00 Fri. 7.30 - 16.15
PRCD-S + personal protection switch

PRCD-S + personal protection switch

3-way coupling IP 44

This article is from the THL assortment!

166,67 €

plus VAT

198,34 €

incl. VAT
article in stock
order number: 99022976
plus Shipping-costs: after expenditure (see Standard business conditions)
open description
Scope of application:

As a portable residual current circuit breaker with rated differential current IΔn ≤ 30 mA or IΔn ≤ 10mA for alternating currents, pulsating DC residual currents and phase-cut fault currents

Function:

The PRCD-S + is all-pole switching: In case of a fault, the power supply via L and N is interrupted and the signal unit on the device lights up in red Safety remains independent of the protective conductor contact until the acknowledgment of the Error closed. If the error has been corrected, the PRCD-S + can be used with a Press the key again.

Each time it is switched on, a routine check is performed, which is the perfect one Condition of the outlet checked.

The protective conductor circuit (PE) is switched on and off in advance

The existing undervoltage release prevents an automatic Restart after a power failure or power failure.

The existing overvoltage protection detects 400VAC and 220VDC and switches do not do this (a weak point).

The PRCD-S + can not be switched on or switches off when:
  • the protective conductor is interrupted.
  • Error voltage is measured at the protective conductor.
  • Over or under voltage is measured.
  • a conductor break is detected.

When external voltage occurs on the protective conductor, the protective device switches the L and N conductor, but maintains the connection of the protective conductor circuit upright.

Technical specifications:
  • Rated voltage 230V ~ / rated frequency 50Hz / rated current 16A
  • Ambient temperature -25 ° C to + 45 ° C
  • Connection cross section: 1-2.5mm², stripping length: 35mm / stripping length: 7mm
  • Tightening torque Housing screw Strain relief Contact screw Ncm 180 80 80
  • Connection cable type according to the national legal regulations and Provisions of the user country. Cable diameter Ø 9-14mm
  • Degree of protection IP55 • Standards / Regulations DIN VDE 0661 and DGUV Information 203-006 (previously BGI / GUV-I 608)
The PRCD-S + is not to be used with:
  • Refrigeration appliances or similar applications (no automatic restart after power failure)
  • Machines with high inrush currents
  • IT power networks (isolation transformers, power generators, etc ...) For the function of the PRCD-S +, the presence of a protective conductor is absolutely necessary.
close description